{"id":"6ac8954e48a28d98eb9db9cd","timestamp":"2026-10-09T07:18:38.114Z","customerId":1645,"type":"submission.created","idempotencyKey":"ee84327e-27bb-48a8-89a7-85fb3848f668","data":{"data":{"rapportnummer":"WK261577","type":"Onderhoud","klantnaam":"K","adres":"Keers","postcode":"2611 bd","woonplaats":"Delft","telefoonnummer":".","contactpersoon":".","locatieVanDeOpstellingsruimte":"Begane grond","nadereAanduidingOpstellingsruimte":"Opslag","datumInspectie":"2026-10-09","ruimtenummerOpstellingsruimte":".","inspectiebedrijf":"Schouten Techniekgroep B.V.","inspecteurCOinspectie":"D.A. van der Wilden","herinspectie":"Nee","toepassingInstallatie":"Centrale verwarming","installatieIngerichtVoor":"Aardgas","namensDeOpdrachtgever":".","installateursnaam":".","soort":"Rookgasanalyse","typeNr":"300","fabrikaat":"Testo","serieNr":"63493132","soort1":"Drukmeter","typenummer":"I510","fabrikaat1":"Testo","serieNr1":"47643679","soort2":"","typeNr1":"","fabrikaat2":"","serieNr2":"","eindconclusie":"De installatie voldoet aan de voorschriften.","naamVanDeInspecteurBevoegdTotHetUitvoerenVanCOinspectie":"D.A. van der Wilden","certificatienummer":"6909","handtekening":"gridfs://registrationFiles/9f882de4-38c2-4e65-aa7b-a490f9454f41","handtekeningVoorAkkoordInspecteur":"gridfs://registrationFiles/a62063fc-180d-4ea9-ae25-064d9b13cfe1","optioneelMailadres":"","gemetenCOwaardePpmInDeOpstellingsruimteVanGasverbrandingstoestellenVoorAanvangWerkzaamheden":0,"fotoMeter":null,"toestellen":[{"merk":"Remeha","type1":"Quinta pro 65","serienummer":"1709615948530","toestelnummer":"1","type":"C","gemetenCOwaarde":54,"fotoMeetwaarde":"gridfs://registrationFiles/073c9826-e56c-4c0b-8280-8c52eb2df0f6"}],"gemetenCOwaarde":0,"fotoMeetwaarde":null,"zijnDeVoorschriftenVanDeFabrikantVanHetdeBetreffendeGasverbrandingstoestellenAanwezig":"Ja","opmerking":"","foto":null,"isDeVerklaringVanGeschiktheidVanHetCLVsysteemAanwezig":"N.v.t.","opmerking1":"","foto1":null,"isHetVoorschriftVanDeFabrikantEnDeGebruiksaanwijzingVanDeBetreffendeRookmelderAanwezig":"Ja","opmerking2":"","foto2":null,"voldoetDeOpstellingsruimteAanDeVoorschriften":"Ja","opmerking3":"","foto3":null,"voldoetDeCapaciteitVoorDeLuchttoevoerEnVentilatieafvoerAanDeVoorschriften":"Ja","opmerking4":"","foto4":null,"voldoetDeInstallatieVanHetdeBetreffendeGasverbrandingstoestellenAanDeVoorschriften":"Ja","opmerking5":"","foto5":null,"voldoetDeRookgasafvoerAanDeVoorschriften":"Ja","opmerking6":"","foto6":null,"voldoetDeAfstellingVanHetdeGasverbrandingstoestellenAanDeVoorschriften":"Ja","opmerking9":"","foto9":null,"voldoetDeAfstellingVanAanlegVanDeLuchttoevoerEnRookgasafvoerAanDeVoorschriften":"Ja","opmerking7":"","foto7":null,"zijnErUitsluitendDoorDeFabrikantVoorgeschrevenOnderdelenToegepastvervangen":"Ja","opmerking8":"","foto8":null,"isErEenDrukdalingsproefUitgevoerdVanDeGasleidingEnIsDezeAkkoordAlleenVanToepassingBijInBedrijfStelling":"N.v.t.","opmerking10":"","foto10":null,"isErEenControleOpHetGasblokUitgevoerdEnIsDezeAkkoord":"Ja","opmerking11":"","foto11":null,"isDeInstallatieWaterzijdigIngeregeld":"Ja","opmerking12":"","foto12":null,"gasdrukGasmeter":30.2,"gastempGasmeter":12,"gasverbruikOpMeterLaaglast":null,"gasverbruikOpMeterVollast":null,"gasverbruikLaaglast":null,"gasverbruikVollast":null,"branderbelastingOwLaaglast":null,"branderbelastingOwVollast":null,"eenheidSignaalVlamdetector":null,"signaalVlamdetectorLaaglast":null,"signaalVlamdetectorVollast":null,"gasVoordrukLaaglast":28.3,"gasVoordrukVollast":22.1,"branderdrukNaHetGasblokLaaglast":null,"branderdrukNaHetGasblokVollast":null,"afgesteldVermogenToestelLaaglast":null,"afgesteldVermogenToestelVollast":null,"verbrandingsluchttempLaaglast":15.3,"verbrandingsluchttempVollast":15.3,"verbrandingsgastempLaaglast":56,"verbrandingsgastempVollast":57.1,"medium":"Mediumtemperatuur","eenheid":"ºC","mediumLaaglast":69,"mediumVollast":80,"o2Laaglast":5,"o2Vollast":4.7,"cO2Laaglast":8.91,"cO2Vollast":9.08,"cOLaaglast":16,"cOVollast":54,"rendementOwLaaglast":98.4,"rendementOwVollast":98.2,"schoorsteenverliesOwLaaglast":1.6,"schoorsteenverliesOwVollast":1.8,"vlamAlleBelastingstandenStabiel":"Ja","grijptIn":110,"actieMaxThermC":"H","actieMediumbev":"S","inhoudLeidingInMeters":null,"bepalingNietAanpassen":3.6,"bepalingMinimaleTestduur":null,"begindruk":null,"einddruk":null,"drukdaling":null},"meta":{"registrationDate":"1791530318401","guid":"ee84327e-27bb-48a8-89a7-85fb3848f668","instructionId":null,"taskId":null,"compatibilityLevel":"4","version":null,"serialNumber":1563,"hiddenFields":["c414d567c7b975a773fc7ee0f8fc9299","a5d7165d366baad611202905b0b0d52f"],"location":{"latitude":"52.0086658","longitude":"4.3581934"},"device":{"uuid":"457bfdcef348721e","name":"Android 16.0.0 - A17 van Dennis (SM-A176B)","network":"CELLULAR","userAgent":"Mozilla/5.0 (Linux; Android 16; SM-A176B Build/BP4A.251205.006; wv) AppleWebKit/537.36 (KHTML, like Gecko) Version/4.0 Chrome/153.0.8010.38 Mobile Safari/537.36","appVersion":"7.2.3"}},"mailStatuses":null,"id":"6ac8954ea91fc2f2c82f326a","info":{"date":1791530318052,"userId":"dvdw@schoutentechniekgroep.nl","partnerId":"52b2d04912e49d26bd57eeda","customerId":1645,"customerName":"e-formapp","formVersionId":"64f9ded81b7705199ebd09bd","formId":"61a6010813ae49553b8246e0","formName":"CV ketels","summary":"","paid":false,"copy":false,"price":0.0,"credits":0,"resends":0,"applicationArtifactVersion":"64f9ded81b7705199ebd09bd"}}}