{"id":"6a97d9a0b9611752f601b282","timestamp":"2026-09-02T08:09:04.316Z","customerId":1645,"type":"submission.created","idempotencyKey":"fd4b9216-c455-48ce-b5b4-e00fffbc9a70","data":{"data":{"rapportnummer":"WK260532","type":"Onderhoud","klantnaam":"Partou","adres":"Polaris 36","postcode":"3235 gt","woonplaats":"Hellevoetsluis ","telefoonnummer":". ","contactpersoon":".","locatieVanDeOpstellingsruimte":"Cv kast","nadereAanduidingOpstellingsruimte":"Teamkamer","datumInspectie":"2026-09-02","ruimtenummerOpstellingsruimte":".","inspectiebedrijf":"Schouten Techniekgroep B.V.","inspecteurCOinspectie":"D.A. van der Wilden","herinspectie":"Nee","toepassingInstallatie":"Centrale verwarming","installatieIngerichtVoor":"Aardgas","namensDeOpdrachtgever":".","installateursnaam":".","soort":"Rookgasanalyse","typeNr":"300","fabrikaat":"Testo","serieNr":"63493132","soort1":"Drukmeter","typenummer":"i510","fabrikaat1":"Testo","serieNr1":"47003669","soort2":"","typeNr1":"","fabrikaat2":"","serieNr2":"","eindconclusie":"De installatie voldoet aan de voorschriften.","naamVanDeInspecteurBevoegdTotHetUitvoerenVanCOinspectie":"D.A. van der Wilden","certificatienummer":"6909","handtekening":"gridfs://registrationFiles/eca9cb34-ed93-4234-a5b6-38cb0d34d3a2","handtekeningVoorAkkoordInspecteur":"gridfs://registrationFiles/4d25d24b-a81d-46bb-b44d-813d34324f92","optioneelMailadres":"","gemetenCOwaardePpmInDeOpstellingsruimteVanGasverbrandingstoestellenVoorAanvangWerkzaamheden":0,"fotoMeter":null,"toestellen":[{"merk":"Remeha","type1":"Quinta 85","serienummer":"0905006168220","toestelnummer":"1","type":"C","gemetenCOwaarde":57,"fotoMeetwaarde":"gridfs://registrationFiles/2829d52e-cbcb-41c7-8964-52264c713f82"}],"gemetenCOwaarde":0,"fotoMeetwaarde":null,"zijnDeVoorschriftenVanDeFabrikantVanHetdeBetreffendeGasverbrandingstoestellenAanwezig":"Ja","opmerking":"","foto":null,"isDeVerklaringVanGeschiktheidVanHetCLVsysteemAanwezig":"N.v.t.","opmerking1":"","foto1":null,"isHetVoorschriftVanDeFabrikantEnDeGebruiksaanwijzingVanDeBetreffendeRookmelderAanwezig":"Ja","opmerking2":"","foto2":null,"voldoetDeOpstellingsruimteAanDeVoorschriften":"Ja","opmerking3":"","foto3":null,"voldoetDeCapaciteitVoorDeLuchttoevoerEnVentilatieafvoerAanDeVoorschriften":"Ja","opmerking4":"","foto4":null,"voldoetDeInstallatieVanHetdeBetreffendeGasverbrandingstoestellenAanDeVoorschriften":"Ja","opmerking5":"","foto5":null,"voldoetDeRookgasafvoerAanDeVoorschriften":"Ja","opmerking6":"","foto6":null,"voldoetDeAfstellingVanHetdeGasverbrandingstoestellenAanDeVoorschriften":"Ja","opmerking9":"","foto9":null,"voldoetDeAfstellingVanAanlegVanDeLuchttoevoerEnRookgasafvoerAanDeVoorschriften":"Ja","opmerking7":"","foto7":null,"zijnErUitsluitendDoorDeFabrikantVoorgeschrevenOnderdelenToegepastvervangen":"Ja","opmerking8":"","foto8":null,"isErEenDrukdalingsproefUitgevoerdVanDeGasleidingEnIsDezeAkkoordAlleenVanToepassingBijInBedrijfStelling":"N.v.t.","opmerking10":"","foto10":null,"isErEenControleOpHetGasblokUitgevoerdEnIsDezeAkkoord":"Ja","opmerking11":"","foto11":null,"isDeInstallatieWaterzijdigIngeregeld":"Ja","opmerking12":"","foto12":null,"gasdrukGasmeter":39.8,"gastempGasmeter":12,"gasverbruikOpMeterLaaglast":null,"gasverbruikOpMeterVollast":null,"gasverbruikLaaglast":null,"gasverbruikVollast":null,"branderbelastingOwLaaglast":null,"branderbelastingOwVollast":null,"eenheidSignaalVlamdetector":"µA","signaalVlamdetectorLaaglast":null,"signaalVlamdetectorVollast":null,"gasVoordrukLaaglast":27.1,"gasVoordrukVollast":18.7,"branderdrukNaHetGasblokLaaglast":null,"branderdrukNaHetGasblokVollast":null,"afgesteldVermogenToestelLaaglast":null,"afgesteldVermogenToestelVollast":84.2,"verbrandingsluchttempLaaglast":21.5,"verbrandingsluchttempVollast":21.5,"verbrandingsgastempLaaglast":50.2,"verbrandingsgastempVollast":65.7,"medium":"Mediumtemperatuur","eenheid":"ºC","mediumLaaglast":58,"mediumVollast":78,"o2Laaglast":4,"o2Vollast":4.1,"cO2Laaglast":9.47,"cO2Vollast":9.42,"cOLaaglast":55,"cOVollast":57,"rendementOwLaaglast":98.8,"rendementOwVollast":98.2,"schoorsteenverliesOwLaaglast":1.2,"schoorsteenverliesOwVollast":1.8,"vlamAlleBelastingstandenStabiel":"Ja","grijptIn":110,"actieMaxThermC":"H","actieMediumbev":"S","inhoudLeidingInMeters":null,"bepalingNietAanpassen":3.6,"bepalingMinimaleTestduur":null,"begindruk":null,"einddruk":null,"drukdaling":null},"meta":{"registrationDate":"1788336541426","guid":"fd4b9216-c455-48ce-b5b4-e00fffbc9a70","instructionId":null,"taskId":null,"compatibilityLevel":"4","version":null,"serialNumber":1539,"hiddenFields":["a5d7165d366baad611202905b0b0d52f","c414d567c7b975a773fc7ee0f8fc9299"],"location":{"latitude":"51.836085","longitude":"4.1638479"},"device":{"uuid":"457bfdcef348721e","name":"Android 16.0.0 - A17 van Dennis (SM-A176B)","network":"CELLULAR","userAgent":"Mozilla/5.0 (Linux; Android 16; SM-A176B Build/BP4A.251205.006; wv) AppleWebKit/537.36 (KHTML, like Gecko) Version/4.0 Chrome/150.0.7871.181 Mobile Safari/537.36","appVersion":"7.1.56"}},"mailStatuses":null,"id":"6a97d9a05973689ead703c43","info":{"date":1788336544261,"userId":"dvdw@schoutentechniekgroep.nl","partnerId":"52b2d04912e49d26bd57eeda","customerId":1645,"customerName":"e-formapp","formVersionId":"64f9ded81b7705199ebd09bd","formId":"61a6010813ae49553b8246e0","formName":"CV ketels","summary":"","paid":false,"copy":false,"price":0.0,"credits":0,"resends":0,"applicationArtifactVersion":"64f9ded81b7705199ebd09bd"}}}